Modbus Switch
The modbus
switch platform allows you to control Modbus switches.
To use your Modbus switches in your installation, add the following to your configuration.yaml
file:
# Example configuration.yml entry switch: platform: modbus slave: 1 registers: 24: bits: 0: name: My switch 2: name: My other switch coils: 0: name: My coil switch
Configuration variables:
- slave (Required): The number of the slave (ignored and can be omitted if not serial Modbus).
- registers array (Required): The array contains a list of relevant registers to read from.
- number of register (Required): Listing relevant bits. It must contain a
bits
section.- bits array (Required): Listing relevant bits. It must contain a
bits
section.- name (Required): Name of the switch.
- bits array (Required): Listing relevant bits. It must contain a
- number of register (Required): Listing relevant bits. It must contain a
- coils (Optional): A list of relevant coils to read from/write to
- number of coil array (Required):
- name (Required): Name of the coil.
- number of coil array (Required):
Each named bit will create a switch.