KNX Thermostat
The knx
thermostat platform is used as in interface with KNX thermostats.
KNX thermostats use at least 2 group addresses: one for the current temperature and one for the target temperature (named set-point in KNX terms).
To use your KNX thermostats in your installation, add the following to your configuration.yaml
file:
thermostat:
- platform: knx
name: KNX Thermostat
temperature_address: 0/1/1
setpoint_address: 0/1/0
- name (Optional): A name for this devices used within Home assistant
- address (Required): The KNX group address that is used to turn on/off this actuator channel
- temperature_address (Required): The group address that is used to communicate the current temperature. Data format must be datapoint type 9.001 DPT_Value_Temp (2-Octet float value) (see http://www.knx.org/fileadmin/template/documents/downloads_support_menu/KNX_tutor_seminar_page/Advanced_documentation/05_Interworking_E1209.pdf)
- setpoint_address (Required): The group address that is used to set/read the target temperature. Data format must be datapoint type 9.001 DPT_Value_Temp (2-Octet float value). Make sure, you set the read-flag for the thermostat to allow Home Assistant to read the target temperature.
With the current version of the module, no advanced KNX thermostat functionalities (e.g. HVAC mode) are supported.