Site updated at 2016-11-18 20:05:06 UTC
This commit is contained in:
parent
efa91710eb
commit
3b72869231
23 changed files with 47 additions and 36 deletions
|
@ -150,6 +150,17 @@
|
|||
<li><strong>partitions</strong> (<em>Optional</em>): Again, Envisalink boards do not tell us what is in use and what is not, so each partition must be configured with a partition name. If no partition parameter is specified, then no alarm_panel or sensor components are loaded.</li>
|
||||
</ul>
|
||||
|
||||
<p>Supported services:</p>
|
||||
|
||||
<p>The following services are supported by Envisalink and can be used to script or automate the alarm.</p>
|
||||
|
||||
<ul>
|
||||
<li><strong>alarm_disarm</strong>: Disarms the alarm with the user code provided, or the code specified in the configuration.</li>
|
||||
<li><strong>alarm_arm_home</strong>: Arms the alarm in home mode.</li>
|
||||
<li><strong>alarm_arm_away</strong>: Arms the alarm in standard away mode.</li>
|
||||
<li><strong>alarm_trigger</strong>: Trigger an alarm on the Envisalink connected alarm system. For example, a newer zwave/zigbee sensor can now be integrated into a legacy alarm system using a Home Assistant automation.</li>
|
||||
<li><strong>alarm_keypress</strong>: Sends a string of up to 6 characters to the alarm. <em>DSC alarms only</em></li>
|
||||
</ul>
|
||||
|
||||
|
||||