@ -81,10 +81,11 @@
<span class="s">climate</span><span class="pi">:</span>
<span class="pi">-</span> <span class="s">platform</span><span class="pi">:</span> <span class="s">knx</span>
<span class="s">name</span><span class="pi">:</span> <span class="s">HASS-Kitchen.Temperature</span>
<span class="s">temperature_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">6/2/1'</span>
<span class="s">setpoint_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/2'</span>
<span class="s">target_temperature_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/1'</span>
<span class="s">operation_mode_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/3'</span>
<span class="s">temperature_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/1'</span>
<span class="s">setpoint_shift_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/2'</span>
<span class="s">setpoint_shift_state_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/3'</span>
<span class="s">target_temperature_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/4'</span>
<span class="s">operation_mode_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/5'</span>
</code></pre>
</div>
<p>Alternatively, if your device has dedicated binary group addresses for frost/night/comfort mode:</p>
@ -92,12 +93,13 @@
<span class="s">climate</span><span class="pi">:</span>
<span class="pi">-</span> <span class="s">platform</span><span class="pi">:</span> <span class="s">knx</span>
<span class="s">name</span><span class="pi">:</span> <span class="s">HASS-Kitchen.Temperature</span>
<span class="s">temperature_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">6/2/1'</span>
<span class="s">setpoint_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/2'</span>
<span class="s">target_temperature_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/1'</span>
<span class="s">operation_mode_frost_protection_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/3'</span>
<span class="s">operation_mode_night_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/4'</span>
<span class="s">operation_mode_comfort_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/5'</span>
<span class="s">temperature_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/1'</span>
<span class="s">setpoint_shift_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/2'</span>
<span class="s">setpoint_shift_state_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/3'</span>
<span class="s">target_temperature_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/4'</span>
<span class="s">operation_mode_frost_protection_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/5'</span>
<span class="s">operation_mode_night_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/6'</span>
<span class="s">operation_mode_comfort_address</span><span class="pi">:</span> <span class="s1">'</span><span class="s">5/1/7'</span>
</code></pre>
</div>
<p>Configuration variables:</p>
@ -105,9 +107,17 @@
<li><strong>name</strong> (<em>Optional</em>): A name for this device used within Home Assistant.</li>
<li><strong>temperature_address</strong>: KNX group address for reading current room temperature from KNX bus.</li>
<li><strong>target_temperature_address</strong>: KNX group address for reading current target temperature from KNX bus.</li>
<li>
<p><strong>setpoint_address</strong>: KNX group address for basis setpoint</p>
</li>
</ul>
<p>The <code class="highlighter-rouge">knx</code> component sets the desired target temperature by modifying the setpoint_shift. The module provides the following configuration options:</p>
<ul>
<li><strong>setpoint_shift_address</strong>: (<em>Optional</em>) KNX address for setpoint_shift</li>
<li><strong>setpoint_shift_state_address</strong>: (<em>Optional</em>) Explicit KNX address for reading setpoint_shift.</li>
<li><strong>setpoint_shift_step</strong>: (<em>Optional</em>) Defines for step size in Kelvin for each step of setpoint_shift. Default is 0.5 K.</li>
<li><strong>setpoint_shift_min</strong>: (<em>Optional</em>) Minimum value of setpoint shift. Default is “-6”.</li>
<li><strong>setpoint_shift_max</strong>: (<em>Optional</em>) Maximum value of setpoint shift. Default is “6”.</li>
</ul>
<p>The operation modes may be controlled with the following directives:</p>
<ul>
<li><strong>operation_mode_address</strong> (<em>Optional</em>): KNX address for operation mode (Frost protection/night/comfort).</li>
<li><strong>operation_mode_state_address</strong> (<em>Optional</em>): Explicit KNX address for reading operation mode</li>
<li><strong>controller_status_address</strong> (<em>Optional</em>): KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3)</li>