Minimizing of the configuration sample (#1013)
This commit is contained in:
parent
ef7531c297
commit
3d47c6f54b
6 changed files with 7 additions and 16 deletions
|
@ -29,9 +29,9 @@ climate:
|
|||
setpoint_address: 0/1/0
|
||||
```
|
||||
|
||||
- **address** (*Required*): The KNX group address that is used to turn on/off this actuator channel
|
||||
- **address** (*Required*): The KNX group address that is used to turn on/off this actuator channel.
|
||||
- **temperature_address** (*Required*): The group address that is used to communicate the current temperature. Data format must be datapoint type 9.001 DPT_Value_Temp (2-Octet float value), check [details](http://www.knx.org/fileadmin/template/documents/downloads_support_menu/KNX_tutor_seminar_page/Advanced_documentation/05_Interworking_E1209.pdf).
|
||||
- **setpoint_address** (*Required*): The group address that is used to set/read the target temperature. Data format must be datapoint type 9.001 DPT_Value_Temp (2-Octet float value). Make sure, you set the read-flag for the thermostat to allow Home Assistant to read the target temperature.
|
||||
- **name** (*Optional*): A name for this devices used within Home Assistant
|
||||
- **name** (*Optional*): A name for this devices used within Home Assistant.
|
||||
|
||||
With the current version of the module, no advanced KNX thermostat functionalities (e.g. HVAC mode) are supported.
|
||||
|
|
Loading…