fixed typos, spelling mistakes (#3436)

This commit is contained in:
Florian Klien 2017-09-25 22:26:17 +02:00 committed by Fabian Affolter
parent 9d94f28131
commit 3f1972b97b
139 changed files with 209 additions and 209 deletions

View file

@ -13,7 +13,7 @@ ha_iot_class: "Local Polling"
ha_release: 0.44
---
The `envirophat` sensor platform allows you to display information collected by an [Enviro pHAT](https://shop.pimoroni.com/products/enviro-phat) add-on board for the Raspberry Pi. The board featues a wide range of sensors, such as:
The `envirophat` sensor platform allows you to display information collected by an [Enviro pHAT](https://shop.pimoroni.com/products/enviro-phat) add-on board for the Raspberry Pi. The board features a wide range of sensors, such as:
- BMP280 temperature/pressure sensor
- TCS3472 light and RGB colour sensor with two LEDs for illumination
@ -50,7 +50,7 @@ sensor:
Configuration variables:
- **display_options** (*Optional*) array: List of readings to monitor. Default is monitoring all of them:
- **temperature**: ambient temperature in Celsius. Since the sensor is close to the Raspberry Pi, that migth affect the accuracy of the reading (ie. the Pi might heat up the sensor)
- **temperature**: ambient temperature in Celsius. Since the sensor is close to the Raspberry Pi, that might affect the accuracy of the reading (ie. the Pi might heat up the sensor)
- **pressure**: atmospheric pressure in hPa.
- **light**: ambient light, as an integer in the 0-65535 range
- **light_red**: red color reading scaled to the ambient light, as an integer in the 0-255 range
@ -66,7 +66,7 @@ Configuration variables:
- **voltage_1**: voltage reading on Analog In 1 in units of V
- **voltage_2**: voltage reading on Analog In 2 in units of V
- **voltage_3**: voltage reading on Analog In 3 in units of V
- **use_led** (*Optional*) True / False boolean; Default value is False, declaring that the onboard LEDs are *not* used for the color measurements thus these readings are based on the ambient light. If the value is set to True, the onboard LEDs will blink whenever a reading is taken.
- **use_led** (*Optional*) True / False boolean; Default value is False, declaring that the on-board LEDs are *not* used for the color measurements thus these readings are based on the ambient light. If the value is set to True, the on-board LEDs will blink whenever a reading is taken.
### Notes
@ -101,7 +101,7 @@ Add something like the following to your [customize section](/docs/configuration
# Example configuration.yaml entry
group:
enviro_phat_voltages:
name: Enviro pHAT Volages`
name: Enviro pHAT Voltages`
entities:
- sensor.voltage_0
- sensor.voltage_1