Site updated at 2016-02-09 08:28:19 UTC
This commit is contained in:
parent
3d44f30889
commit
4879933bb7
13 changed files with 171 additions and 165 deletions
|
@ -122,6 +122,9 @@
|
|||
<span class="key">name</span>: <span class="string"><span class="content">Study</span></span>
|
||||
<span class="key">heater</span>: <span class="string"><span class="content">switch.study_heater</span></span>
|
||||
<span class="key">target_sensor</span>: <span class="string"><span class="content">sensor.study_temperature</span></span>
|
||||
<span class="key">min_temp</span>: <span class="string"><span class="content">15</span></span>
|
||||
<span class="key">max_temp</span>: <span class="string"><span class="content">21</span></span>
|
||||
<span class="key">target_temp</span>: <span class="string"><span class="content">15</span></span>
|
||||
</pre></div>
|
||||
</div>
|
||||
</div>
|
||||
|
@ -132,6 +135,9 @@
|
|||
<li><strong>name</strong> (<em>Required</em>): Name of thermostat</li>
|
||||
<li><strong>heater</strong> (<em>Required</em>: <code>entity_id</code> for heater switch, must be a toggle device.</li>
|
||||
<li><strong>target_sensor</strong> (<em>Required</em>): <code>entity_id</code> for a temperature sensor, target_sensor.state must be temperature.</li>
|
||||
<li><strong>min_temp</strong> (<em>Optional</em>): Set minimum set point available (default: 7)</li>
|
||||
<li><strong>max_temp</strong> (<em>Optional</em>): Set maximum set point available (default: 35)</li>
|
||||
<li><strong>target_temp</strong> (<em>Required</em>): Set default target temperature. Failure to set this variable will result in target temperature being set to null on startup.</li>
|
||||
</ul>
|
||||
|
||||
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue