@ -2,7 +2,7 @@
|
|||
layout: page
|
||||
title: "MySensors"
|
||||
description: "Instructions how to integrate MySensors sensors into Home Assistant."
|
||||
date: 2016-02-15 17:37 +0100
|
||||
date: 2016-02-18 20:13 +0100
|
||||
sidebar: true
|
||||
comments: false
|
||||
sharing: true
|
||||
|
@ -31,6 +31,7 @@ mysensors:
|
|||
debug: true
|
||||
persistence: true
|
||||
version: '1.5'
|
||||
optimistic: 'true'
|
||||
```
|
||||
|
||||
Configuration variables:
|
||||
|
@ -41,6 +42,7 @@ Configuration variables:
|
|||
- **persistence_file** (*Optional*): Path to a file to save sensor information. The file extension determines the file type. Currently supported file types are 'pickle' and 'json'.
|
||||
- **version** (*Optional*): Specifies the MySensors protocol version to use. Supports 1.4 and 1.5. Default is 1.4.
|
||||
- **baud_rate** (*Optional*): Specifies baud rate of the connected gateway. Default is 115200.
|
||||
- **optimistic** (*Optional*): Enable or disable optimistic mode for actuators (switch/light). Default is false. Set this to true if no state feedback from actuators is possible. Home Assistant will assume that the command succeeded and change state.
|
||||
|
||||
If you are using an original Arduino the port will be named `ttyACM*`. The exact number can be determined with the command shown below.
|
||||
|
||||
|
|