layout: page
|
||||
title: "Heat control"
|
||||
description: "Turn Home Assistant into a thermostat"
|
||||
date: 2015-03-23 19:59
|
||||
sidebar: false
|
||||
comments: false
|
||||
sharing: true
|
||||
footer: true
|
||||
---
|
||||
|
||||
Specify a start time, end time and a target temperature.
|
||||
If the the current temperature is lower than the target temperature,
|
||||
and the time is between start time and end time, the heater will
|
||||
be turned on. Opposite if the the temperature is higher than the
|
||||
target temperature the heater will be turned off.
|
||||
|
||||
If away mode is activated the target temperature is sat to a min
|
||||
temperature (min_temp in config). The min temperature is also used
|
||||
as target temperature when no other temperature is specified.
|
||||
|
||||
If the heater is manually turned on, the target temperature will
|
||||
be sat to 100*C. Meaning
|
||||
the thermostat probably will never turn off the heater.
|
||||
If the heater is manually turned off, the target temperature will
|
||||
be sat according to normal rules. (Based on target temperature
|
||||
for given time intervals and the min temperature.)
|
||||
|
||||
A target temperature sat with the set_temperature function will
|
||||
override all other rules for the target temperature.
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
thermostat:
|
||||
platform: heat_control
|
||||
name: Stue
|
||||
|
||||
# entity_id for heater switch, must be a toggle device
|
||||
heater: switch.Ovn_stue
|
||||
|
||||
# entity_id for temperature sensor, target_sensor.state must be temperature
|
||||
target_sensor: tellstick_sensor.Stue_temperature
|
||||
|
||||
# start_time-end_time:target_temp,
|
||||
time_temp: 0700-0745:17,1500-1850:20
|
||||
|
||||
# minimum temperature, used when away mode is active or
|
||||
# no other temperature specified.
|
||||
min_temp: 10
|
||||
```
|
||||
|
||||
For the example the heater will turn on at 0700 if the temperature
|
||||
is lower than 17C away mode is false. Between 0700 and 0745 the
|
||||
target temperature will be 17C. Between 0745 and 1500 no temperature
|
||||
is specified. so the min_temp of 10C will be used. From 1500 to 1850
|
||||
the target temperature is 20, but if away mode is true the target
|
||||
temperature will be sat to 10C
|