add disarm_after_trigger to manual alarm panel
This commit is contained in:
parent
1e3f7ad9a4
commit
abaffc2d8c
4 changed files with 91 additions and 22 deletions
|
@ -7,28 +7,46 @@ https://home-assistant.io/components/alarm_control_panel.manual/
|
|||
import datetime
|
||||
import logging
|
||||
|
||||
import voluptuous as vol
|
||||
|
||||
import homeassistant.components.alarm_control_panel as alarm
|
||||
import homeassistant.util.dt as dt_util
|
||||
from homeassistant.const import (
|
||||
STATE_ALARM_ARMED_AWAY, STATE_ALARM_ARMED_HOME, STATE_ALARM_DISARMED,
|
||||
STATE_ALARM_PENDING, STATE_ALARM_TRIGGERED)
|
||||
STATE_ALARM_PENDING, STATE_ALARM_TRIGGERED, CONF_PLATFORM, CONF_NAME,
|
||||
CONF_CODE, CONF_PENDING_TIME, CONF_TRIGGER_TIME, CONF_DISARM_AFTER_TRIGGER)
|
||||
import homeassistant.helpers.config_validation as cv
|
||||
from homeassistant.helpers.event import track_point_in_time
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
DEFAULT_ALARM_NAME = 'HA Alarm'
|
||||
DEFAULT_PENDING_TIME = 60
|
||||
DEFAULT_TRIGGER_TIME = 120
|
||||
DEFAULT_DISARM_AFTER_TRIGGER = False
|
||||
|
||||
PLATFORM_SCHEMA = vol.Schema({
|
||||
vol.Required(CONF_PLATFORM): 'manual',
|
||||
vol.Optional(CONF_NAME, default=DEFAULT_ALARM_NAME): cv.string,
|
||||
vol.Optional(CONF_CODE): cv.string,
|
||||
vol.Optional(CONF_PENDING_TIME, default=DEFAULT_PENDING_TIME):
|
||||
vol.All(vol.Coerce(int), vol.Range(min=1)),
|
||||
vol.Optional(CONF_TRIGGER_TIME, default=DEFAULT_TRIGGER_TIME):
|
||||
vol.All(vol.Coerce(int), vol.Range(min=1)),
|
||||
vol.Optional(CONF_DISARM_AFTER_TRIGGER,
|
||||
default=DEFAULT_DISARM_AFTER_TRIGGER): cv.boolean,
|
||||
})
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
def setup_platform(hass, config, add_devices, discovery_info=None):
|
||||
"""Setup the manual alarm platform."""
|
||||
add_devices([ManualAlarm(
|
||||
hass,
|
||||
config.get('name', DEFAULT_ALARM_NAME),
|
||||
config.get('code'),
|
||||
config.get('pending_time', DEFAULT_PENDING_TIME),
|
||||
config.get('trigger_time', DEFAULT_TRIGGER_TIME),
|
||||
config[CONF_NAME],
|
||||
config.get(CONF_CODE),
|
||||
config.get(CONF_PENDING_TIME, DEFAULT_PENDING_TIME),
|
||||
config.get(CONF_TRIGGER_TIME, DEFAULT_TRIGGER_TIME),
|
||||
config.get(CONF_DISARM_AFTER_TRIGGER, DEFAULT_DISARM_AFTER_TRIGGER)
|
||||
)])
|
||||
|
||||
|
||||
|
@ -40,10 +58,12 @@ class ManualAlarm(alarm.AlarmControlPanel):
|
|||
|
||||
When armed, will be pending for 'pending_time', after that armed.
|
||||
When triggered, will be pending for 'trigger_time'. After that will be
|
||||
triggered for 'trigger_time', after that we return to the previous state.
|
||||
triggered for 'trigger_time', after that we return to the previous state
|
||||
or disarm if `disarm_after_trigger` is true.
|
||||
"""
|
||||
|
||||
def __init__(self, hass, name, code, pending_time, trigger_time):
|
||||
def __init__(self, hass, name, code, pending_time,
|
||||
trigger_time, disarm_after_trigger):
|
||||
"""Initalize the manual alarm panel."""
|
||||
self._state = STATE_ALARM_DISARMED
|
||||
self._hass = hass
|
||||
|
@ -51,6 +71,7 @@ class ManualAlarm(alarm.AlarmControlPanel):
|
|||
self._code = str(code) if code else None
|
||||
self._pending_time = datetime.timedelta(seconds=pending_time)
|
||||
self._trigger_time = datetime.timedelta(seconds=trigger_time)
|
||||
self._disarm_after_trigger = disarm_after_trigger
|
||||
self._pre_trigger_state = self._state
|
||||
self._state_ts = None
|
||||
|
||||
|
@ -78,7 +99,10 @@ class ManualAlarm(alarm.AlarmControlPanel):
|
|||
return STATE_ALARM_PENDING
|
||||
elif (self._state_ts + self._pending_time +
|
||||
self._trigger_time) < dt_util.utcnow():
|
||||
return self._pre_trigger_state
|
||||
if self._disarm_after_trigger:
|
||||
return STATE_ALARM_DISARMED
|
||||
else:
|
||||
return self._pre_trigger_state
|
||||
|
||||
return self._state
|
||||
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue