* Additional documentation Added documentation for additional parameters introduced by a separate change request (already included in 0.48) KNX should be moved from the "DIY" section as KNX isn't a DIY solution, but an industry standard used for building automatisation. * Removed some example code
37 lines
1.4 KiB
Markdown
37 lines
1.4 KiB
Markdown
---
|
|
layout: page
|
|
title: "KNX Cover"
|
|
description: "Instructions on how to integrate KXN covers with Home Assistant."
|
|
date: 2017-06-18 12:00
|
|
sidebar: true
|
|
comments: false
|
|
sharing: true
|
|
footer: true
|
|
logo: knx.png
|
|
ha_category: Cover
|
|
ha_release: 0.48
|
|
ha_iot_class: "Local Polling"
|
|
---
|
|
|
|
|
|
The `knx` cover platform is used as in interface with KNX covers.
|
|
|
|
To use your KNX covers in your installation, add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
cover:
|
|
- platform: knx
|
|
updown_address: 9/0/0
|
|
stop_address: 9/0/1
|
|
```
|
|
|
|
- **name** (*Optional*): A name for this devices used within Home Assistant.
|
|
- **updown_address** (*Required*): The KNX group address that is used to move the cover up and down.
|
|
- **stop_address** (*Required*): The group address that is used to stop the cover.
|
|
- **setposition_address** (*Optional*): The group address that is used to set the position.
|
|
- **getposition_address** (*Optional*): The group address that is used to read the position.
|
|
- **setangle_address** (*Optional*): The group address that is used to set the tilt angle.
|
|
- **getangle_address** (*Optional*): The group address that is used to read the tilt angle.
|
|
- **invert_position** (*Optional*): Set this to true if your actuator report fully closed as 100%
|
|
- **invert_angle** (*Optional*): Set this to true if your actuator reports tilt fully closed as 100%
|