* Added required dependency Since release 0.27.1 it became mandatory to define apcupsd and associated server and port. Missing configuration was not caught by validation script and it prevented all other sensors from loading. See more here: https://community.home-assistant.io/t/0-27-1-broke-customize * Updated per review Followed @Landrash advise for cleaner approach
107 lines
2.3 KiB
Markdown
107 lines
2.3 KiB
Markdown
---
|
|
layout: page
|
|
title: APCUPSd Sensor
|
|
description: "Instructions on how to set up APCUPSd sensors within Home Assistant."
|
|
date: 2016-02-10 18:28
|
|
sidebar: true
|
|
comments: false
|
|
sharing: true
|
|
footer: true
|
|
logo: apcupsd.png
|
|
ha_category: Sensor
|
|
---
|
|
|
|
The `apcupsd` sensor platform allows you to monitor a UPS (battery backup) by using data from the [apcaccess](http://linux.die.net/man/8/apcaccess) command.
|
|
|
|
To use this sensor platform, you first have to set up [apcupsd](https://home-assistant.io/components/apcupsd/) and add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
sensor:
|
|
- platform: apcupsd
|
|
resources:
|
|
- bcharge
|
|
- linev
|
|
- loadpct
|
|
- nominv
|
|
- nompower
|
|
- numxfers
|
|
- outputv
|
|
- status
|
|
- timeleft
|
|
- tonbatt
|
|
```
|
|
|
|
Configuration variables:
|
|
|
|
- **resources** array (*Required*): Contains all entries to display.
|
|
|
|
### {% linkable_title Example %}
|
|
|
|
Given the following output from `apcaccess`:
|
|
|
|
```yaml
|
|
APC : 001,051,1149
|
|
DATE : 2016-02-09 17:13:31 +0000
|
|
HOSTNAME : localhost
|
|
VERSION : 3.14.12 (29 March 2014) redhat
|
|
UPSNAME : netrack
|
|
CABLE : Custom Cable Smart
|
|
DRIVER : APC Smart UPS (any)
|
|
UPSMODE : Stand Alone
|
|
STARTTIME: 2016-02-09 16:06:47 +0000
|
|
MODEL : SMART-UPS 1400
|
|
STATUS : TRIM ONLINE
|
|
LINEV : 247.0 Volts
|
|
LOADPCT : 13.0 Percent
|
|
BCHARGE : 100.0 Percent
|
|
TIMELEFT : 104.0 Minutes
|
|
MBATTCHG : 5 Percent
|
|
MINTIMEL : 3 Minutes
|
|
MAXTIME : 0 Seconds
|
|
MAXLINEV : 249.6 Volts
|
|
MINLINEV : 244.4 Volts
|
|
OUTPUTV : 218.4 Volts
|
|
SENSE : High
|
|
DWAKE : 0 Seconds
|
|
DSHUTD : 180 Seconds
|
|
DLOWBATT : 2 Minutes
|
|
LOTRANS : 196.0 Volts
|
|
HITRANS : 253.0 Volts
|
|
RETPCT : 15.0 Percent
|
|
ITEMP : 30.6 C
|
|
ALARMDEL : Low Battery
|
|
BATTV : 27.6 Volts
|
|
LINEFREQ : 50.0 Hz
|
|
LASTXFER : High line voltage
|
|
NUMXFERS : 0
|
|
TONBATT : 0 Seconds
|
|
CUMONBATT: 0 Seconds
|
|
XOFFBATT : N/A
|
|
SELFTEST : NO
|
|
STESTI : 336
|
|
STATFLAG : 0x0500000A
|
|
DIPSW : 0x00
|
|
REG1 : 0x00
|
|
REG2 : 0x00
|
|
REG3 : 0x00
|
|
MANDATE : 07/13/99
|
|
SERIALNO : GS9888761008
|
|
BATTDATE : 13/11/15
|
|
NOMOUTV : 230 Volts
|
|
NOMBATTV : 24.0 Volts
|
|
EXTBATTS : 0
|
|
FIRMWARE : 70.11.I
|
|
END APC : 2016-02-09 17:13:46 +0000
|
|
```
|
|
|
|
Use the (case insensitive) values from the left hand column:
|
|
|
|